Discover how the different vent types work and their installation requirements. Use our product selector tool to choose the correct model for your home. Determine the best location for the intake/vent. such as a direct vent water heater or concentric vent tankless model. We recommend that you consult a professional plumbing contractor for installation. A. O. Smith expands Vertex™ high-efficiency line with power direct vent 75-gallon gas water … with Power Direct Vent 75-gallon Gas Water Heater 2014-03-03 Ashland City, Tenn.—Leading water heater … water heater, the Vertex™ 100 Power Direct Vent … Protect condensation, and it is preferable to install power or direct vent or horizontal venting. natural gas and propane, the Polaris features a power direct vent design that fits with PVC, CPVC … steel. 100316044. best suited for use when there is insufficient ventilation within the installation space in your home. Rinnai RU199iN RRU199iN, RU199in-Natural Gas/11 GPM & Diversitech CVENT-3 Concentric Vent Termination Kit Concentric venting describes any coaxial "pipe in pipe" venting design where the intake air and exhaust gas both vent through a shared assembly. Add to List. ... 39" Concentric Straight Pipe Vent, Takagi/State/AO Smith 100266135. slider closed. ©2018, A. O. Smith. Direct vent gas water heaters Get tips and more information on water hardness, why it matters, and how to solve it. Item # 1076464 Model # 100303709. Smith Gas Tankless water heaters are available in condensing and non-condensing units to fit your needs. Find answers in product info, Q&As, reviews. Usually ships within 2 to 3 days. Cut a 4" diameter hole for 1CT0302, 2" kit, or a 5" hole for 1CT0303, 3" kit. Much like direct venting, power direct venting uses a blower to pull in air from outside your home for combustion and funnels it directly to your water heater. This jig is designed to precisely guide cuts to the inner aluminum pipe 12cm (3/8") proud of the outer PVC pipe. $35.99. Power vents are a more efficient option, as they are designed to utilize heat from the exhaust to heat water for energy savings. a) Cement Y concentric fitting to larger diameter kit pipe, see Figure . Prime members enjoy FREE Delivery and exclusive access to music, movies, TV shows, original audio series, and Kindle books. Match the flow rate to your customer's needs. 2. See Fig. Additionally, two front-access panels give contractors simple access to all serviceable … 5. page 30 6 inch concentric termination installation intake air connection 6” x 4” bushing intake air pipe (factory 6” x 6” x 6” vent pipe installed) y fitting vent maintain 12” (30 cm) 18” (45 cm) for canada minimum clearance above highest anticipated combustion snow level. Brief content visible, double tap to read full content. are used when the space in which you are installing a water heater lacks sufficient air for combustion and requires flexibility around the installation. Brand: AO Smith (1)-+ $54.69 each ADD TO CART. There was a problem completing your request. Download our water heater installation instructions. From the Manufacturer. Concentric venting may be used with several types of water heaters, including direct vent, power direct vent, and tankless water heaters. I was able to merge dual piping and run it out the exiting exhaust hole. A.O. Help others learn more about this product by uploading a video! Can be used with ATI-310. hansgrohe iBox Universal Leak Preventing Valve Rough-in with Service Stop for Stand... Stiebel Eltron 239223 Tankless Water Heater – Tempra 29 Plus – Electric, On Demand ... OdorHog Vent Stack Pipe Filter 4.0", Black ABS with Mushroom Cap, Removes Outdoor S... Deflect-O RVHAW3 Bathroom or Dryer Vent Hood-Wide Mouth Hood ~ 3", Camplux 10L 2.64 GPM High Capacity Color Screen Propane Tankless Water Heater. Similar to the power vent design, a power direct vent water heater can utilize PVC piping to reduce installation costs. b) Cement 4” x 6” (10 cm x 15 cm) bushings to Y fitting, see Figure . Partially assemble concentric vent termination kit. The box was beat up, but the way it was packed was the problem. I would recommend this part to anyone. There was an error retrieving your Wish Lists. Please make sure that you are posting in the form of a question. work great. The venting must be vertical or upward sloping so that the hot exhaust rises up through the venting to exit your home. AO Smith 100266135 - 39" Straight Concentric Pipe Vent Kit - 39" Straight Concentric Pipe Vent Kit. Review the factors you'll need to weigh before making a decision. 4. Your recently viewed items and featured recommendations, Select the department you want to search in. AO Smith 100113124 Concentric Vent Kit, 6" x 6" x 48", 636, 100113124 Cement air inlet and exhaust vent pipes to concentric vent termination assembly. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. With a wide range of water heating solutions that work for many different applications, our Signature gas water heaters can get you back into hot water quickly. Two Concentric Vent products are available: CVENT-2 is for use AO Smith 9007611005 Concentric Termination PVC, PVC (polyvinyl chloride) concentric vent 3" hub allows incoming air and outgoing exhaust in a single termination outlet assembly used for condensing tankless models TS-340 and TS-540 heaters, Previous page of related Sponsored Products. 3. Maintain the same vent pipe diameter from the water heater flue to the termination. Full content visible, double tap to read brief content. All Rights Reserved. Please try again. This uses the Takagi Proprietary APNC35 Concentric Vent Design which allows for an extremely long maximum venting length of 43 feet and up to 4 elbows. A. O. Smith power vent gas water heaters It is important to note that they also require an electrical outlet near the water heater for installation. Concentric vent kit simplifies installation, saving time and cost. 3. Please try your search again later. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires, see Figure 9(page 10) and Figure 10 (page 14). are the most common type of When connecting to a 4 in. 35.99. Clean and cement using procedures explained in the furnace They are available in either 3” or 6” and in multiple lengths. The use of a concentric vent kit allows for both the intake for combustion air and the exhaust vent to pass through one termination in a standard roof or sidewall; This is an alternative to the standard two pipe intake and vent system in most power direct vent installations