Provide Temporary Not Occupied Override, 1-255 days. 2 Outdoor control sensor (select heat pumps) ** See page 11 3 Indoor sensor 0350 Heat pump compressor lockout 0 No heat pump compressor lockout Other options: 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60 °F (-15 °C to 15.5 °C) 0360 Heat pump auxiliary lockout 0 No heat pump auxiliary lockout Other options: View and Download Honeywell THX9321 Prestige 2.0 system installation ... (see table below) Heat pump only Backup heat lockout Heat pump with backup heat as needed * Compressor lockout Backup heat only No backup heat ... , Backup Heat Upstage Timer and Outdoor Temperature Lockouts. Thermostat controls backup heat (outdoor sensor required) Recommended for most compressors [Other options: 1, 2, 4, ... compressor lockout Heat pump auxiliary lockout Dehumidification control 5 3 9 5 3 9 9 3 5 O O 3 O 2 o O 2 3 O O O ... Honeywell International Inc. Provide wiring diagrams for every controller 17. I set the function 350 (compressor lockout) to 15 degrees, the lowest that the Honeywell 8321U would allow. 12. I have the dual fuel type of heat pump and want to know how I can disable the emergency heat mode on the Honeywell thermostat. THX9321 PRESTIGE ® 2.0 AND THX9421 PRESTIGE ® IAQ WITH EIM. I control that temperature through my WIFI Thermostat. Outdoor temp.0342 sensor E Auto Discover ** 0 None 1 Remote sensor 0345Dual fuel heat pump control 1 Droop Control ** 0 No Droop Control ** 2 Droop Control with Aux Heat Lockout ** 0346Dual fuel heat pump upstage to furnace timer (in hours) 1 1 hour ** 0 Off [Other options: 0.5, 1.5, 2-6, 8, 10, 12, 14, 16 hours] 0347Droop temperature 2 Default Fig. Honeywell TH8321 User Manual. 13. You have been successfully registered. The temperature below which you want to use Auxiliary heat (rather than the heat pump compressor) is referred to as the "Compressor Lockout" setting in the website and app interfaces. T-stat controls a Carrier heat pump/gas furnace (dual system, heat pump is also A/C). Option 9 (Heat Pump Lockout): Set at Of(f), the compressor (heat pump) will always run (with the auxiliary) no matter how low is the outdoor temp. if there is anything else i can check let me know. Caution, entering installer set -up mode may result in altering settings Do not press the + or buttons when in the installer set– -up (ISU) or settings will be altered Full screen Standard. System is currently set to "economy". It may be set for compressor lockout, dual fuel, or auxiliary lockout with no outdoor sensor. For example, if your AUX lockout temp is 40ºF or 4.4ºC, then AUX heat will come on when the outdoor temperature drops below 40ºF or 4.4ºC. David Butler. Download. Note: Normal programmable thermostats have one way to control AUX heat: the AUX lockout temperature.If it gets colder outside than the set lockout temperature, your heat pump will use AUX heat. We have a Honeywell VisionPro TH8320 t-stat and I was looking at the setup menu this morning. Below this temperature, only electric heat operates. Get consistent comfort with basic push-button operation, accurate within +/- 1° F on this Honeywell Home Digital Non-Programmable Heat-Cool Pump Thermostat. Manualsbrain.com. 0 Thermostat controls backup heat (outdoor sensor required) 0220 1st stage com- ... 2 Droop control with aux heat lockout 0346 Dual fuel heat pump upstage to furnace timer ** 1 1 hour 0 Off ... Honeywell International Inc. d. NOTE- If no outdoor sensor is installed or enabled, lockouts will be displayed as OFF and are not adjustable That did not change the settings allowed for function 360 (aux lockout) below the previously set 40 degrees and the aux heat still comes on at any temperature below 40 degrees. Heat Pump Control — Electric Backup (Setup Functions 0350-0360): If an outdoor temperature sensor is installed, select a compressor lockout temperature (Function 0350). Like. Auxillary Heat implies that you have an Air Source Heat Pump. 68-0311—02. The two options are "comfort (off)" and "economy". These two values can be set in the Installer Menu 312: "Outdoor Lockout-Backup Heat" and "Outdoor Lockout HeatPump" So lets say Balance point is 25* F and Compressor lockout is … Typical hookup of conventional multistage two-stage heating and two-stage cooling in a two-transformer system (2H/2C or 2H/1C or 1H/2C conventional). PTCS Heat Pump Thermostat Support Sheet Manufacturer: Honeywell Thermostat Models: T6 Pro TH6320U2008, TH6220U2000, TH6210U2001 Page 1 of 2. Honeywell TH8320 manual : INSTALLER SETUP. Connect the outdoor sensor to the EIM using the Wireless Setup function. Honeywell Home RTH9585WF1004 Wi-Fi Smart Color Thermostat, 7 Day Programmable, Touch Screen, Energy Star, Alexa Ready 4.4 out of 5 stars 7,331 $126.80 $ 126 . Welcome to ManualMachine. Please check your inbox, and if you can’t find it, check your spam folder to make sure it didn't end up there. TH8320U AND TH8321U TOUCH SCREEN PROGRAMMABLE THERMOSTATS 5 69-1706 Fig. 1. This extra heat kicks on at a preset temperature. Page 21 T10 PRO … The outdoor lockout heat pump setting on the thermostat is set at 60 degrees and the outdoor lockout backup heat is set at 65 degrees. ** For the Honeywell 8000 series if “Wait” is displayed, the compressor protection timer is on. We have emailed you a verification link to to complete your registration. : Honeywell Honeywell-Visionpro-Th8000-Series-Installation-Manual-120099 honeywell-visionpro-th8000-series-installation-manual-120099 honeywell pdf The Auxiliary Heat Lockout setting is displayed on the right and must be set to 35 degrees or lower to meet spec . This sensor allows the honeywell thermostat to control humidity and ventilation indoors, taking into account outdoor temperature and humidity. Honeywell TH8320 manual : INSTALLER SETUP. US Patent No. Operation in Heat Mode. View and Download Honeywell 69-2092EFS-07 instruction manual online. 2. ... Heat Pump with Electric Auxiliary (Backup) Heat and Outdoor Temperature Sensor. It allows locking out the heat pump when outdoor temperature falls below the breakeven temperature. Provide heat lockout based on a window/door switch and freeze protection so the zone will not drop below a configurable temperature if lockout is active 16. Installer Setup (ISU) Installer Setup ISU # Name Settings Default Notes 3120 Backup Heat Fahrenheit: This ISU is used to lockout the auxiliary heat Lockout when outdoor temperature is above this 5° F to 65° F (in 5° F setting. Insert two fresh AA Lithium batteries in it. What is this setting and what would changing it actually do? ... and Auxiliary Heat Lockout Temperatures. If E53 is still there, outdoor sensor is not connecting properly. I am in the installer setup now This is great for analyzing the performance of a heat pump, and setting lockout temperatures. 100. Mine is not Honeywell, so check your instructions. It also adjusts indoor humidity in order to avoid condensation on the inside of the windows. Manufacturer: Honeywell Thermostat Models: Prestige IAQ Page 2 of 2. compressor lockout and auxiliary heat lockout. d. Room temp, setpoint and outdoor air 14. 80 $199.00 $199.00 If set to a specific temperature (i.e. You can also set alert ranges - for example, if delta T on air conditioning or heat pumping drops below a certain threshold, that could indicate loss of refrigerant or a dirty indoor or outdoor coil, and put an alert on the thermostat advising the owner to take action. The thermostat shall have a compressor outdoor lockout and bac kup heat outdoor lockout to turn off the heat pump or backup heat based on outdoor temperature. Typical hookup of single-stage heat pump with no auxiliary/backup heat (1H/1C heat pump). 35), the compressor is locked-out and ONLY the auxiliary will run when the outdoor temp drops below the specified temp. 15. 2 Outdoor control sensor (select heat pumps) ** See page 11 3 Indoor sensor 0350 Heat pump compressor lockout 0 No heat pump compressor lockout Other options: 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60 °F (-15 °C to 15.5 °C) 0360 Heat pump auxiliary lockout 0 No heat pump auxiliary lockout Other options: